Warning: Invalid argument supplied for foreach() in /home/saversys/public_html/libraries/joomla/database/database/mysql.php on line 383
MasonrySaver Garage Floor Sealer

Warning: Invalid argument supplied for foreach() in /home/saversys/public_html/libraries/joomla/database/database/mysql.php on line 383

Warning: Invalid argument supplied for foreach() in /home/saversys/public_html/libraries/joomla/database/database/mysql.php on line 383

Warning: Invalid argument supplied for foreach() in /home/saversys/public_html/libraries/joomla/database/table.php on line 406

Warning: Invalid argument supplied for foreach() in /home/saversys/public_html/libraries/joomla/database/database/mysql.php on line 383

Warning: Invalid argument supplied for foreach() in /home/saversys/public_html/libraries/joomla/database/database/mysql.php on line 383

Warning: Invalid argument supplied for foreach() in /home/saversys/public_html/libraries/joomla/database/table.php on line 406

Warning: Invalid argument supplied for foreach() in /home/saversys/public_html/libraries/joomla/database/database/mysql.php on line 383

MasonrySaver Garage Floor Sealer

  • Print
Product Datasheets

MasonrySaver Garage Floor Sealer is a non-yellowing acrylic polymer blend sealer formulated for sealing properly cured concrete surfaces.

Product Uses

Garage Floor Sealer is suitable for use on a variety of surfaces where a durable gloss finish is desired including garage floors, concrete patios, driveways and sidewalks. It leaves an attractive, durable, gloss finish that protects concrete from moisture, oil stains and abrasion/wear.

LIMITATIONS: Not suitable for use over asphalt surfaces. Do not use on below-grade surfaces that are subject to severe hydro-static pressures. When using in areas subjected to hot tire traffic, allow adequate time for product to cure before putting the area back into service. When applying over previous coating, hot tire resistance maybe compromised.  Do not use if the area will be exposed to softer, high performance tires. Product will not withstand brake fluid and will need to be reapplied in areas where brake fluid spills have occured.

Product Benefits

  • Protects concrete surfaces from oil spills and stains
  • Stands up to hot tire traffic
  • Can be applied over previously coated surfaces
  • Extremely durable, high gloss finish
  • Low odor, water-based formula

Directions for Use

Surface Preparation: Always test in an inconspicuous area to ensure desired results. Protect all non-targeted surfaces that may come in to contact with the product. Use polyethylene or other tested material for protecting other surfaces, such as glass, foliage, siding or painted surfaces. Cover all openings including windows and doors prior to application. During use, avoid wind drift that may injure pedestrians, damage vehicles or adjacent properties. Remove any overspray immediately with soap and water. Dry film can be removed using a razor scraper. When using, surface to receive application should be clean and dry. Absorbed moisture should not be present. New construction should cure for a period of 30 days.

FOR NEW CONCRETE: Use MasonrySaver No-Rinse Etch to etch the surface. Allow to set for 30 minutes then apply Garage Floor Sealer. Note that No-Rinse Etch will etch the surface but does not clean any dirt or staining. If concrete needs to be cleaned and etched, use MasonrySaver Safer Masonry Cleaner. Please note that using Safer Masonry Cleaner will require a thorough rinsing with water and 3-5 days dry time.

FOR EXISTING CONCRETE: If the surface is already clean, No-Rinse Etch can be used for etching followed by a sealer application 30 minutes later. Otherwise use MasonrySaver Safer Masonry Cleaner to remove dust, curing compounds, efflorescence, coatings and other foreign materials in order to expose a clean, sound surface. It is extremely important to rinse the surface thoroughly with water after using Safer Masonry Cleaner to bring the substrate to a neutral ph level (7). Testing with ph paper should be done prior to using Garage Floor Sealer to ensure that a neutral ph has been achieved. After rinsing, surface should be allowed to dry a minimum of 3-5 days prior to sealing. Applying sealer over an acidic substrate will most likely result in failure. If oil or grease stains are present, use MasonrySaver Cleaner & Degreaser to remove stains prior to cleaning/etching.

Mixing: Material may separate during long-term storage so mix thoroughly before use.

Application

Apply two uniform coats of material to new, previously untreated concrete surfaces. Allow the first coat of material to dry sufficiently to walk on, but not more than 4 hours, prior to application of the second coat. MasonrySaver Garage Floor Sealer may be sprayed applied using a pump-up, “garden type” sprayer with fan type nozzle, with an airless sprayer, pad appliactor or by roller. If roller applied, use a short nap cover. Avoid puddling or ponding of product: brush or roll material until it thoroughly penetrates the surface. Block all drains and use absorptive coverings to contain run-off or excess material. Use soap and water to remove overspray as soon as possible.

CAUTION: Treated surfaces may become slick when wet. To provide a non-skid surface, consider broadcasting silica sand, synthetic aggregate or other skid-resistant additive to surface per aggregate manufacturer's instructions. For more information and specific recommendations, please visit saversystems.com/nonskid.

Drying Time: One to two hours, depending on temperature and humidity. Allow 4 - 6 hours cure time before exposing to foot traffic. Allow 6 days cure time before exposure to heavy traffic, such as forklifts, automobiles, etc.

Clean Up: Thoroughly rinse spray equipment with clean water. Clean applicators with soap and water. Rinse thoroughly.
Coverage: 100 - 150 square feet per gallon on concrete. Note: coverage rates will vary based on the porosity of the substrate.

Cautions

Keep out of reach of children. Keep container closed. Eye irritant. Avoid contact with eyes, mucous membranes and prolonged contact with skin. The use of chemical splash gloves and a NIOSH approved respirator, effective against ammonia inhalation, is highly recommended when using this product.

First Aid: If swallowed DO NOT induce vomiting. Drink 1 – 2 glasses of water or milk to dilute the product and seek medical help immediately. In case of eye contact; flush with water immediately, remove contact lenses and continue to flush with water for at least fifteen minutes. Seek medical attention. For contact with skin; wash as soon as possible with soap and plenty of water. If redness occurs seek medical attention.

Limited Warranty

Our recommendations for use of this product are based upon tests believed to be reliable. Since field conditions vary widely, the user must determine the suitability of the product for the particular use and specific method(s) of application. Due to the fact that SaverSystems has no control over surface preparation and application methods, no guarantee as to results is offered, expressed or implied. SaverSystems warrants this product to be free from manufacturing defects.

SaverSystems’ liability shall be limited, in all events, to supplying sufficient product to re-treat the specific areas to which defective product has been applied. This warranty does not cover the cost of labor for application. SaverSystems shall have no other liability including direct, incidental or consequential damages. Some states do not allow the exclusion of incidental or consequential damages so this limitation or exclusion may not apply to you. This warranty gives you specific legal rights. You may also have other rights, which vary from state to state.

Packaging

Available in one gallon recyclable plastic containers.

Transport and Storage

MasonrySaver Garage Floor Sealer is not considered hazardous under Department of Transportation (DOT) regulations. Do not stack pallets. Keep from freezing.

Maintenance

Remove all contaminants which might stain or abrade treated surfaces as quickly as possible to minimize staining and abrasion. Occasional cleaning with a mild detergent and water will generally restore treated surfaces to original appearance. When MasonrySaver Garage Floor Sealer begins to appear worn from the surface, a single coat of material may be applied once surface has been properly prepared. Avoid applying maintenance coat more frequently than every 18 – 24 months to avoid excessive build-up of material on surface. When build-up of product does become excessive, surface should be thoroughly stripped of product followed by application of two coats of material.

 

  • Details
  • Technical Info
Size Approx. Weight Product Code UPC #
1 gal 9 lbs 300421 709057035019

  • Coverage Rate (all per gal) : 1,500-2,000 sq. ft. per coat
  • Available Sizes: 1 gallon container
  • Application Method:Pump-up Sprayer, Mop or Pad Applicator
  • Dry Time: Allow 24 hours before buffing.
  • Cleanup: Soap and Water